| GNOME MODBUS-SNMP Converter |
| SNMP Converter for IGS-NT Family Controllers |
| |
| General information |
- A SNMP agent for ComAp NT line controllers
- Connected to the controllers via RS485 (Modbus)
- Up to 32 controllers served by one device
- Provides access to basic operational and statistic values (not configurable) using GET transaction
- Generates a TRAP event if any protection occurs in the controller
- Mode change and basic genset control is also available via SET transaction
|
 |
|
| |
| I-AOUT8 |
| 8 Analog Outputs Interface Unit |
| |
| General information |
- 8 analog outputs extension module
- Applicable to: InteliSys, InteliDrive, IGS-NT
- Up to four I-AOUT8 can be connected to one controller
- Outputs are configurable to:
- 0-10VDC or
- 0/4-20mA range or
- 1200 Hz pwm
- UL certified
|
 |
|
| |
| I-CB/CAT DIESEL |
| Communication Bridge for Caterpillar/CCM |
| |
| General information |
- Versatile programmable interface unit
between Inteli NT, InteliSys or InteliDrive
controller and CCM
- For diesel engines
- UART interface
- Selected analog and binary values are
received from CCM via I-CB
- UL certified
|
 |
| |
|
|
| |
| I-CB/CAT GAS |
| Communication Bridge for Caterpillar/CCM |
| |
| General information |
- Versatile programmable interface unit
between Inteli NT, InteliSys or InteliDrive
controller and CCM
- For gas engines
- UART interface
- Selected analog and binary values are
received from CCM via I-CB
- UL certified
|
 |
| |
|
|
| |
| I-CB/Deutz TEME |
| Communication Bridge for Deutz/TEM Evolution |
| |
| General information |
- Programmable interface unit between Inteli NT, InteliSys or InteliDrive controller and Deutz TEM Evolution unit
- Configured analog and binary values, alarms and faults are received from Deutz TEM Evolution unit via I-CB and displayed on IS measurement screens
- UART interface
- UL certified
|
 |
|
| |
| I-CB/MTU |
| Communication Bridge for MTU/MDEC |
| |
| General information |
- Versatile programmable interface unit
between Inteli NT, InteliSys or InteliDrive
controller and the Engine Control
Unit
- CAN bus interface
- Selected analog and binary values are
received from ECU via i-CB
- UL certified
|
 |
| |
|
|
| |
| I-CR |
| CAN Repeater Module |
| |
| General information |
Used for CAN
bus extension in cases where the maximum
distance limit would be exceeded.
- Intercontroller CAN bus extension (one
or more I-CR modules can be used)
- Intercontroller CAN bus bus-tie bridging -
makes groups of controllers in segments
A and B "invisible" one for another depending
on bus-tie breaker state, keeping the
PC communication (IG-MU, IG-IB) in function
for all controllers
- Peripheral CAN bus extension
|
 |
| |
|
|
| |
| IG-AVRi |
| AVR Interface |
| |
| General information |
- Interface between IG-PCM/PCLSM, InteliSys or Inteli NT cotroller and generator AVR
|
 |
|
| |
| IG-AVRi/Marine |
| AVR Interface - Marine Version |
| |
| General information |
- Acknowledged by Germanischer Lloyd
- Connects IG-PCM/PCLSM with generator AVR
|
 |
|
| |
| IG-AVRi-TRANS/100 |
| Transformer for IG-AVRi Module |
| |
| General information |
- Primary voltage: 100 - 120 VAC +- 20%
- Frequency range: 50 - 60 Hz
- Designed for HV or MV applications
|
 |
|
| |
| IG-AVRi-TRANS/LV |
| Power Supply Transformer for IG-AVRi Module |
| |
| General information |
- Primary voltage 1: 230 - 277 VAC +-
20%
- Primary voltage 2: 400 - 480 VAC
+- 20%
- Frequency range: 50 - 60 - 400 Hz
|
 |
| |
|
|
| |
| IG-AVRi-TRANS/Marine |
| Transformer for IG-AVRi Module |
| |
| General information |
- Primary voltage 1: 230 - 277 VAC +- 20%
- Primary voltage 2: 400 - 480 VAC +- 20%
- Frequency range: 50 - 60 - 400 Hz
|
 |
|
| |
| IG-COM |
| Communication Unit |
| |
| General information |
- Enables communication among InteliGen/InteliMains controllers via CAN bus
- Enables Power management feature of InteliGen controllers
- Attached at the back of InteliGen/InteliMains controller
|
 |
|
| |
| IG-COM/Marine |
| Communication Unit - Marine Version |
| |
| General information |
- Acknowledged by Germanischer Lloyd
- Enables communication among InteliGen/InteliMains
controllers via CAN bus
- Enables Power management feature of
InteliGen controllers
- Attached at the back of InteliGen/InteliMains
controller
|
 |
| |
|
|
| |
| IG-Display |
| Secondary Display Module for IG-NT Controllers |
| |
| General information |
| Graphic display module for IG-NT controllers. Serves as a secondary display to the basic controller display, providing remote (up to 1200 m) monitoring and control of a gen-set. |
 |
|
| |
| IG-IB |
| Internet Bridge |
| |
| General information |
- Using Internet Bridge you can easily
service and monitor your gen-set even
from the other side of earth
- Enables internet connection between
controllers (IGS-NT, InteliGen, InteliSys,
InteliDrive) and superior service or monitoring
software (GenConfig, InteliMonitor, InteliSupervisor, IGS-LOG,
WinEdit, MultiEdit, DriveConfig or DriveMonitor)
- Ethernet or dial-up connection of the
controller to the internet
- Supports single/multiple gen-set control
via Internet
- Sends active e-mails in case of alarm
on site
- For more gen-sets additional hardware
key (IG-IB3, IG-IB7, IG-IB15, IG-IB32)
is required
- UL certified
|
 |
| |
|
|
| |
| IG-IOM |
| Input/Output Module |
| |
| General information |
- Input and output extension module
- 8 binary and 4 analog inputs
- 8 binary and 1 analog output
- Connection via CAN bus
- Not galvanic separated
|
 |
| |
|
|
| |
| IG/IS-NT MultiKit |
| Simulator of Multiple Gen-set Applications with IG/IS-NT |
| |
| General information |
IG/IS-NT MultiKit
- Small switchboard for testing multiple gen-set applications
- Contains three InteliGen NT / InteliSys NT, 1 InteliMains NT, Engine and Mains simulators
- Controllers are connected with load sharing line and CAN bus
- Shared connection to all controllers via built-in I-LB (for PC monitoring)
|
 |
|
| |
| IG/IS-NT On-line StarterKit |
| Internet Access Simulator for IG/IS-NT Controllers |
| |
| General information |
On-line controller - you can test the IG/IS-NT controller functionality and setting on-line; all you need to do is to download and install IG/IS-NT Installation package and manuals.
How to connect to the controller:
- Start InteliMonitor, click on Open connection icon, select Connect to selected site, select IS-internet site and click on Open connection.
- It is necessary to unlock controller if you want to edit setpoints. Click on the lock icon or press Ctrl+P to open Login window. Select User as the user name and write 0 as the password.
- It may happen that somebody else is already connected to the on-line controller (up to 4 users can be connected to the controller at the same time) and signed up for controller setpoints editing. Attempt to login may be followed by error message: Invalid password/New controller 1. Please, try to login later if this message is displayed.
This controller is available via analog modem, too. Phone number you have to dial is +420 284 825 909.
Please note, that available on-line controller is the IS-NT StarterKit controller. It means:
- Mains current simulation is not available in the IS-NT StarterKit, therefore power Export/Import simulation is not possible.
- Features and setpoints of the IS-NT controller which are not available in the IG-NT controller are marked in manual with cyan background.
Do not hesitate to contact us if you have any questions regarding controller setting or functions.
|
 |
|
| |
| IGL-RA15 |
| Remote Annunciator |
| |
| General information |
- Extension signalling unit for InteliLite,
InteliGen, or InteliSys gen-set controllers
- 15 LEDs with configurable colors red-green-yellow
- Customizable labels
- Local horn output
- Lamp test function
- Connected via CAN bus, max distance
200m from the controller
- UL certified
|
 |
| |
|
|
| |
| IG-MTU |
| Mains Transformer Unit |
| |
| General information |
- Set of 3 mains voltage transformers 400V/230V
- Galvanic separation of the mains and generator voltage
- For three wire system, system with separated Neutral or when galvanic separation between generator or mains voltage and controller is required
|
 |
|
| |
| IG-MTU-2-1 |
| Mains Transformer Unit |
| |
| General information |
- Set of three mains voltage step down transformers 600V/300V (transformer ratio 2:1)
- For applications where mains/bus/generator voltage is higher than controller measuring range
- Galvanic separation of the mains and generator voltage
- For three wire system, system with separated Neutral or when galvanic separation between generator or mains voltage and controller is required
|
 |
|
| |
| IG-MTU Marine |
| Mains Transformer Unit |
| |
| General information |
- For marine applications
- Set of 3 mains voltage transformers 400V/230V
- Galvanic separation of the bus and generator voltage
|
 |
|
| |
| IG-MTU-C |
| Separation Transformers Unit |
| |
| General information |
- Set of 3 mains voltage transformers 400V/230V
- For three wire system, system with separated Neutral or when galvanic separation between generator or mains voltage and controller is required
- Additional filter for the cases of extreme distortion of generator voltage by higher harmonics due to inverters etc.
|
 |
|
| |
| IG-MU |
| Modem Unit |
| |
| General information |
- Direct or modem control of multiple gen-sets
- RS422/RS485/ModBus support for direct connection
- Analog/GSM/ISDN modem support
- Modem callback function
- UL certified
|
 |
|
| |
| IG-PCLSM |
| Load Sharing Module |
| |
| General information |
- For isolated parallel or parallel to
mains operation
- Analog isochronous load sharing line
- Automatic forward and reverse synchronizing
- Speed/voltage control
- Load control including ramping
- Power factor, import/export control
- Additional 4 binary inputs and outputs
|
 |
| |
|
|
| |
| IG-PCLSM/Marine |
| Load Sharing Module - Marine Version |
| |
| General information |
- Acknowledged by Germanischer Lloyd
- For isolated parallel operation
- Analog isochronous load sharing line
- Automatic forward and reverse synchronizing
- Speed/voltage control
- Soad control including ramping
- Sower factor, import/export control
- Additional 4 binary inputs and outputs
|
 |
| |
|
|
| |
| IG-PCM |
| Power Control Module |
| |
| General information |
- For parallel to mains operation
- Automatic forward and reverse synchronizing
- Speed/voltage control
- Load control including ramping
- Power factor, import/export control
- Additional 4 binary inputs and outputs
|
 |
| |
|
|
| |
| IGS-NT-LSM+PMS |
| Hardware Key for Load Sharing and Power Management |
| |
| General information |
Enables multiple
isolated parallel or multiple parallel with
mains operation (with CAN bus)
- Digital Load Sharing
- Digital VAr Sharing
- Optimizing number of running engines:
Power management; kW, kVA or % load based
|
 |
| |
|
|
| |
|
| Combined hardware key |
| |
| General information |
| This module combines the features provided by IGS-NT-LSM+PMS and IGS-NT-miniCHP modules.
|
 |
|
| |
| IGS-NT-miniCHP |
| Hardware Key for mini-CHP (up to 30 kW) units |
| |
| General information |
Enables to increase the number of PLC functions used with IG-NT/EE controllers to allow the design of a simple CHP unit. Special set of archives should be used with this module: IG-apl_name-mCHP-version.
Actual number of available PLC functions can be found in Application guide for NT controllers. |
 |
|
| |
| IGS-PTM |
| Input/Output Module |
| |
| General information |
- Input and output extension module
- 8 binary and 4 analog inputs
- 8 binary and 1 analog output
- Measures values from Pt100 and Ni100
sensors
- Analog inputs have maximum resistance
range 0-250 Ohms, voltage range 0-100mV,
current range 0-20mA - selectable via
jumper
- UL certified
|
 |
| |
|
|
| |
| I-LB / I-LB+ |
| Local Bridge |
| |
| General information |
- Bridge for sites with multiple controllers for local or remote monitoring and control
- Direct, modem or USB (I-LB+ version only) connection to multiple controllers
- RS232 / RS485 / ModBus support for direct connection
- Communication speed up to 57600 bps (including ModBus mode)
- Analog / GSM / ISDN / CDMA modem support
|
 |
|
| |
| I-LBA |
| Low Battery Adaptor |
| |
| General information |
Module connected between 12 V DC battery and controller power terminals to support controller operation during battery voltage dips.
- Suitable for InteliGen/Inteli NT/InteliLite controllers
- Keeps the controller operating during battery voltage drop, e.g. while the engine is cranking
|
 |
|
| |
| IL-NT AOUT8 |
| Gauge Plug-in Interface for IL-NT |
| |
| General information |
- Gauge driver plug-in interface
- Applicable to InteliLite NT (IL-NT)
- Up to 8 gauges (VDO, Datcon,...) can be driven by one controller
|
 |
|
| |
| IL-NT RS232 |
| RS232 Extension Board for IL-NT |
| |
| General information |
- Extension board containing RS232 port for InteliLite NT (IL-NT) controllers
|
 |
|
| |
| InteliGen NT StarterKit |
| Portable Simulator for InteliGen NT Controller |
| |
| General information |
InteliGen NT StarterKit
- Includes one InteliGen NT controller
- All binary inputs are connected to switches
- Binary output states are indicated by LEDs
- Analogue inputs changeable by potentiometers
- Connection to PC via RS232 serial line
|
 |
|
| |
| InteliGen® MultiKit |
| Simulator of Multiple Gen-set Applications with InteliGen |
| |
| General information |
InteliGen®
MultiKit
|
 |
| |
|
|
| |
| InteliGen® StarterKit |
| Portable Simulator for InteliGen Controller |
| |
| General information |
InteliGen®
StarterKit
- Includes one InteliGen controller
- All binary inputs are connected to switches
- Binary output states are indicated by
LEDs
- Analogue inputs changeable by potentiometers
- Connection to PC via RS232 serial line
|
 |
| |
|
|
| |
| InteliLite® StarterKit |
| Portable Simulator for InteliLite Controller |
| |
| General information |
InteliLite®
StarterKit
- Includes one InteliLite controller
- All binary inputs are connected to switches
- Binary output states are indicated by
LEDs
- Analogue inputs changeable by potentiometers
- Connection to PC via RS232 serial line
|
 |
| |
|
|
| |
| InteliSys AB Kit |
| Analog-Binary I/O Extension Kit |
| |
| General information |
- Unit with extension modules IS-AIN8
and IS-BIN16/8
- All binary and analogue inputs can be
simulated
- Outputs are indicated by LEDs
- IS-AB Kit can be connected to IS- or
ID-Starter kit
|
 |
| |
|
|
| |
| InteliSys NT StarterKit |
| Portable Simulator for InteliSys NT Controller |
| |
| General information |
InteliSys NT StarterKit
- Includes one InteliSys NT controller
- All binary inputs are connected to switches
- Binary output states are indicated by LEDs
- Analog inputs changeable by potentiometers
- Connection to PC via RS232 serial line
|
 |
|
| |
| InteliSys® MultiKit |
| Simulator of Multiple Gen-set Applications with InteliSys |
| |
| General information |
InteliSys®
MultiKit
|
 |
| |
|
|
| |
| InteliSys® StarterKit |
| Portable Simulator for InteliSys Controller |
| |
| General information |
InteliSys®
StarterKit
- Contains one InteliSys controller
- All binary inputs connected to alteration
switches
- Binary output states indicated by LEDs
- Analog input values changeable by potentiometers
- Connection to PC via RS232 serial line
|
 |
| |
|
|
| |
| InteliVision |
| Controller Display Unit |
| |
| General information |
- New generation display unit for either IGS-NT or ID controllers
- 8" colour TFT display with resolution of 800 × 600 pixels
- Controlled by active buttons TRENDS monitoring screen as a standard feature
- Developed from IS-Display Windows CE operating system
- Simpler, faster and more intuitive control
- More information in less time
- Same language support as IGS-NT and ID
- Screen configuration by customer - export to XML format with subsequent manual screen modification and import back to the controller (as IS-Display)
- Direct connection to the controller (converters are not needed)
- The same dimensions as IS-Display / IS-NT (including cut out dimensions)
- It is possible to mount IS-NT-BB to the rear side of InteliVision
- Can be used as a replacement for (or an alternative to) IG-Display, IS-Display or I-RD-CAN
- Plug and Play operation (auto configuration based on controller application)
- Designed to be mounted in both monitoring and engine room
- This display gives complete access to all control and monitoring functions when connected to IGS-NT / ID controllers
- Universal solution - one type of display for both controller families - IGS-NT and ID
- Intended for connection to ONE controller (IGS-NT or ID)
- Connection to a controller via RS232/485 and CAN bus
- Operating temperature from -20 to + 70°C (-4/158°F)
- Sealed to IP65
|
|
|
| |
| I-RB8 |
| 8 Relay Board |
| |
| General information |
- 8 relays in sockets
- Both n.o. and n.c. contacts available
- 24 VDC supply
- 16A resistive and 4 A inductive load at 24 VDC
- DIN rail design
|
 |
|
| |
| I-RB8-231 |
| 8 Relay Board |
| |
| General information |
- 8 relays in socket
- Both n.o. and n.c. contacts
- 24 VDC supply
- 2 Amps load at 231 VAC
- DIN rail design
|
 |
|
| |
| I-RB16 |
| 16 Relay Board |
| |
| General information |
- 16 relays in socket
- Both n.o. and n.c. contacts
- 24VDC supply
- 16A resistive and 4 A inductive load at 24 VDC
- DIN rail design
|
 |
|
| |
| I-RB16-231 |
| 16 Relay Board |
| |
| General information |
- 16 relays in socket
- Both n.o. and n.c. contacts
- 24VDC supply
- 2 Amps load at 231 VAC
- DIN rail design
|
 |
|
| |
| I-RD |
| Remote Display |
| |
| General information |
- Remote signalling and control unit with RS232 interface
- For InteliGen and InteliLite gen-set controllers
- Gen-set can be controlled from I-RD as well as from master controller
- I-RD screens display the same as master controller
- Buttons and LEDs have the same function
- Order code I-RD/IG-CU, I-RD/AMF25, I-RD/MRS10, etc
|
 |
|
| |
| IS-AIN8 |
| Analogue Input Module |
| |
| General information |
- 8 analogue inputs
- Connection via CAN bus
- Precision of inputs is 1%
- Accept 2/3 wire resistive, current,
voltage senders
- UL certified
|
 |
| |
|
|
| |
| IS-BIN16/8 |
| Binary Input/Output Module |
| |
| General information |
- 16 inputs and 8 transistor outputs
- Inputs galvanically separated
- 2 pulse inputs (frequency measurement
or pulse counting)
- Connection via CAN bus
- UL certified
|
 |
| |
|
|
| |
| IS-Display |
| Detachable Display Module for IS-NT Controllers |
| |
| General information |
Powerful graphic
display module for IS-NT controllers. Up
to 3 displays can be connected to one Base
Box module (IS-NT-BB), providing both local
and remote (up to 1200 m) monitoring and
control of a gen-set. |
 |
| |
|
|
| |
| IS-PCLSM Dongle |
| InteliSys Power Control and Load Sharing Module HW Key |
| |
| General information |
- Required for MINT application
Enables:
- Synchronizing and load control
- Voltage and PF control
- Load and VAR sharing
|
 |
| |
|
|
| |
| IS-PCLSM-PMS Dongle |
| InteliSys-Power Control and Load Sharing-Power Management HW |
| |
| General information |
Enables in
MINT application:
- Synchronizing and load control
- Voltage and PF control
- Load and VAR sharing
- Power management
|
 |
| |
|
|
| |
| IS-PCM Dongle |
| InteliSys Power Control Module HW Key |
| |
| General information |
- Required for SPtM and SPI applications
- Enables synchronizing and load control
- Enables voltage and PF control
|
 |
| |
|
|
| |
| IS-RD |
| Remote Display |
| |
| General information |
- Remote signalling and control unit with RS232 interface
- For InteliSys
- Gen-set can be controlled from IS-RD as well as from master controller
- IS-RD screens display the same as master controller
- Buttons and LEDs have the same function
|
 |
|
| |
| NT-Converter |
| Load Sharing Interface Module for IG/IS-NT |
| |
| General information |
NT-Converter is an interface module for IG/IS-NT controllers. It allows to connect them into an existing system consisting of some third-party gen-set controllers (Woodward, Barber-Colman, ...) or IG/IS classic line controllers via their analog Load Sharing lines and CAN2 bus.
NT-Converter-1.1 allows to connect one IG/IS-NT controller into a system consisting of third-party controllers with Load Sharing capability. The connection via CAN bus allows to use Var sharing and synchronized parameters.
One logical group can be created with several IG-CU or IS-CU and with IG/IS-NT. The module allows controller monitoring via IG-MU, IG-IB or I-LB/I-LB+.
|
 |
|
| |