I AOUT8
8 Analog Outputs Interface Unit
 
General information
  • 8 analog outputs extension module
  • Applicable to: InteliSys, InteliDrive, IGS-NT
  • Up to four I-AOUT8 can be connected to one controller
  • Outputs are configurable to: 
  • 0-10VDC or
  • 0/4-20mA range or
  • 1200 Hz pwm
  • UL certified
 
ID COM
InteliDrive Communication Module
 
General information
  • Interface for CAN1 Extension and J1939 modules
  • Interface for CAN2 Inter-controller and I-RD-CAN modules
  • Interface for J1708 redundancy line
  • UL certified
 
 Download PDF
 
ID RPU
Redundant Protection Unit
 
General information
  • Backup module for marine engines
  • Automatic switchover between primary and secondary power supply
  • Monitors function of main InteliDrive unit
  • In case of main unit failure switches to the backup mode and protects the engine
  • RPM input with hardwired overspeed protection
  • 5 shutdown channels with Broken Wire detection
  • Fuel and Stop solenoids with BW detection
 
 Download PDF
 
ID SCM
InteliDrive - Speed Control Module
 
General information

Interface module for InteliDrive controllers for full support of internal PLC (programmable logic) in wide range of industrial applications.

Module is mounted directly on ID-DCU controller body. Module I/O:

  • RPM1, RPM2: Inputs for frequency measuring - up to 8 kHz
  • IMP1, IMP2: Inputs for integral (consumption) measuring up to 60 Hz
  • AOUT1, AOUT2: Analog outputs 0 - 10VDC or 0 - 20 mA
  • Speed Governor Output: ±10VDC or ±10VDC via 10kΩ or PWM (1,6kHz ) 
  • UL certified
 
 Download PDF
 
IGL RA15
Remote Annunciator
 
General information
  • Extension signalling unit for InteliLite, InteliGen, or InteliSys gen-set controllers
  • 15 LEDs with configurable colors red-green-yellow
  • Customizable labels
  • Local horn output
  • Lamp test function
  • Connected via CAN bus, max distance 200m from the controller
  • UL certified
 
 Download PDF
 
IGS PTM
Input/Output Module
 
General information
  • Input and output extension module
  • 8 binary and 4 analog inputs
  • 8 binary and 1 analog output
  • Measures values from Pt100 and Ni100 sensors
  • Analog inputs have maximum resistance range 0-250 Ohms, voltage range 0-100mV, current range 0-20mA - selectable via jumper
  • UL certified
 
 Download PDF
 
InteliDrive® Industrial StarterKit
Portable Simulator for InteliDrive Controller
 
General information
  • InteliDrive Binary and Analog inputs simulation
  • InteliDrive Binary outputs indication
  • ID-SCM (Speed Control Module) simulation
 
InteliDrive® Marine StarterKit
Portable Simulator for InteliDrive Controller
 
General information
  • InteliDrive Binary and Analog inputs simulation
  • InteliDrive Binary outputs indication
  • ID-RPU I/O simulation and indication
  • ID-DCU and ID-RPU RPM simulation
 
InteliVision
Controller Display Unit
 
General information
  • New generation display unit for either IGS-NT or ID controllers
  • 8" colour TFT display with resolution of 800 × 600 pixels
  • Controlled by active buttons TRENDS monitoring screen as a standard feature
  • Developed from IS-Display Windows CE operating system
  • Simpler, faster and more intuitive control
  • More information in less time
  • Same language support as IGS-NT and ID
  • Screen configuration by customer - export to XML format with subsequent manual screen modification and import back to the controller (as IS-Display)
  • Direct connection to the controller (converters are not needed)
  • The same dimensions as IS-Display / IS-NT (including cut out dimensions)
  • It is possible to mount IS-NT-BB to the rear side of InteliVision
  • Can be used as a replacement for (or an alternative to) IG-Display, IS-Display or I-RD-CAN
  • Plug and Play operation (auto configuration based on controller application)
  • Designed to be mounted in both monitoring and engine room
  • This display gives complete access to all control and monitoring functions when connected to IGS-NT / ID controllers
  • Universal solution - one type of display for both controller families - IGS-NT and ID
  • Intended for connection to ONE controller (IGS-NT or ID)
  • Connection to a controller via RS232/485 and CAN bus
  • Operating temperature from -20 to + 70°C (-4/158°F)
  • Sealed to IP65
 Download PDF
 
I RB8
8 Relay Board
 
General information
  • 8 relays in sockets
  • Both n.o. and n.c. contacts available
  • 24 VDC supply
  • 16A resistive and 4 A inductive load at 24 VDC
  • DIN rail design
 
I RB8 231
8 Relay Board
 
General information
  • 8 relays in socket
  • Both n.o. and n.c. contacts
  • 24 VDC supply
  • 2 Amps load at 231 VAC
  • DIN rail design
 
I RB16
16 Relay Board
 
General information
  • 16 relays in socket
  • Both n.o. and n.c. contacts
  • 24VDC supply
  • 16A resistive and 4 A inductive load  at 24 VDC
  • DIN rail design
 
I-RB16-231
16 Relay Board
 
General information
  • 16 relays in socket
  • Both n.o. and n.c. contacts
  • 24VDC supply
  • 2 Amps load at 231 VAC
  • DIN rail design
 
I RD CAN
Remote Display with CAN Bus Interface
 
General information
  • Remote control panel for the ID-DCU master controller
  • Applicable up to 900 meters distance from master controller
  • The same front facia, LED's and button handling
 
IS AIN8
Analogue Input Module
 
General information
  • 8 analogue inputs
  • Connection via CAN bus
  • Precision of inputs is 1%
  • Accept 2/3 wire resistive, current, voltage senders
  • UL certified
 
 Download PDF
 
IS BIN16/8
Binary Input/Output Module
 
General information
  • 16 inputs and 8 transistor outputs
  • Inputs galvanically separated
  • 2 pulse inputs (frequency measurement or pulse counting)
  • Connection via CAN bus
  • UL certified
 
 Download PDF
 
Home | Company Profile | Products | Dealership | Experience Certificates | Sales & Services | Brouchers | Rantal
Vacancies | Career | Enquiry Form | Contact us
Copyright © 2008 R.A. Engineering & Services. All right reserved. Website designed by PNT Global