| I AOUT8 |
| 8 Analog Outputs Interface Unit |
| |
| General information |
- 8 analog outputs extension module
- Applicable to: InteliSys, InteliDrive, IGS-NT
- Up to four I-AOUT8 can be connected to one controller
- Outputs are configurable to:
- 0-10VDC or
- 0/4-20mA range or
- 1200 Hz pwm
- UL certified
|
 |
|
| |
| ID COM |
| InteliDrive Communication Module |
| |
| General information |
- Interface for CAN1 Extension and J1939
modules
- Interface for CAN2 Inter-controller
and I-RD-CAN modules
- Interface for J1708 redundancy line
- UL certified
|
 |
| |
|
|
| |
| ID RPU |
| Redundant Protection Unit |
| |
| General information |
- Backup module for marine engines
- Automatic switchover between primary
and secondary power supply
- Monitors function of main InteliDrive
unit
- In case of main unit failure switches
to the backup mode and protects the engine
- RPM input with hardwired overspeed protection
- 5 shutdown channels with Broken
Wire detection
- Fuel and Stop solenoids with BW detection
|
 |
| |
|
|
| |
| ID SCM |
| InteliDrive - Speed Control Module |
| |
| General information |
Interface module
for InteliDrive controllers for full support
of internal PLC (programmable logic) in
wide range of industrial applications.
Module is mounted directly on ID-DCU controller
body. Module I/O:
- RPM1, RPM2: Inputs for frequency
measuring - up to 8 kHz
- IMP1, IMP2: Inputs for integral
(consumption) measuring up to 60 Hz
- AOUT1, AOUT2: Analog outputs 0
- 10VDC or 0 - 20 mA
- Speed Governor Output: ±10VDC
or ±10VDC via 10kΩ or PWM
(1,6kHz )
- UL certified
|
 |
| |
|
|
| |
| IGL RA15 |
| Remote Annunciator |
| |
| General information |
- Extension signalling unit for InteliLite,
InteliGen, or InteliSys gen-set controllers
- 15 LEDs with configurable colors red-green-yellow
- Customizable labels
- Local horn output
- Lamp test function
- Connected via CAN bus, max distance
200m from the controller
- UL certified
|
 |
| |
|
|
| |
| IGS PTM |
| Input/Output Module |
| |
| General information |
- Input and output extension module
- 8 binary and 4 analog inputs
- 8 binary and 1 analog output
- Measures values from Pt100 and Ni100
sensors
- Analog inputs have maximum resistance
range 0-250 Ohms, voltage range 0-100mV,
current range 0-20mA - selectable via
jumper
- UL certified
|
 |
| |
|
|
| |
| InteliDrive® Industrial StarterKit |
| Portable Simulator for InteliDrive Controller |
| |
| General information |
- InteliDrive Binary and Analog inputs simulation
- InteliDrive Binary outputs indication
- ID-SCM (Speed Control Module) simulation
|
 |
|
| |
| InteliDrive® Marine StarterKit |
| Portable Simulator for InteliDrive Controller |
| |
| General information |
- InteliDrive Binary and Analog inputs simulation
- InteliDrive Binary outputs indication
- ID-RPU I/O simulation and indication
- ID-DCU and ID-RPU RPM simulation
|
 |
|
| |
| InteliVision |
| Controller Display Unit |
| |
| General information |
- New generation display unit for either IGS-NT or ID controllers
- 8" colour TFT display with resolution of 800 × 600 pixels
- Controlled by active buttons TRENDS monitoring screen as a standard feature
- Developed from IS-Display Windows CE operating system
- Simpler, faster and more intuitive control
- More information in less time
- Same language support as IGS-NT and ID
- Screen configuration by customer - export to XML format with subsequent manual screen modification and import back to the controller (as IS-Display)
- Direct connection to the controller (converters are not needed)
- The same dimensions as IS-Display / IS-NT (including cut out dimensions)
- It is possible to mount IS-NT-BB to the rear side of InteliVision
- Can be used as a replacement for (or an alternative to) IG-Display, IS-Display or I-RD-CAN
- Plug and Play operation (auto configuration based on controller application)
- Designed to be mounted in both monitoring and engine room
- This display gives complete access to all control and monitoring functions when connected to IGS-NT / ID controllers
- Universal solution - one type of display for both controller families - IGS-NT and ID
- Intended for connection to ONE controller (IGS-NT or ID)
- Connection to a controller via RS232/485 and CAN bus
- Operating temperature from -20 to + 70°C (-4/158°F)
- Sealed to IP65
|
|
|
| |
| I RB8 |
| 8 Relay Board |
| |
| General information |
- 8 relays in sockets
- Both n.o. and n.c. contacts available
- 24 VDC supply
- 16A resistive and 4 A inductive load at 24 VDC
- DIN rail design
|
 |
|
| |
| I RB8 231 |
| 8 Relay Board |
| |
| General information |
- 8 relays in socket
- Both n.o. and n.c. contacts
- 24 VDC supply
- 2 Amps load at 231 VAC
- DIN rail design
|
 |
|
| |
| I RB16 |
| 16 Relay Board |
| |
| General information |
- 16 relays in socket
- Both n.o. and n.c. contacts
- 24VDC supply
- 16A resistive and 4 A inductive load at 24 VDC
- DIN rail design
|
 |
|
| |
| I-RB16-231 |
| 16 Relay Board |
| |
| General information |
- 16 relays in socket
- Both n.o. and n.c. contacts
- 24VDC supply
- 2 Amps load at 231 VAC
- DIN rail design
|
 |
|
| |
| I RD CAN |
| Remote Display with CAN Bus Interface |
| |
| General information |
- Remote control panel for the ID-DCU master controller
- Applicable up to 900 meters distance from master controller
- The same front facia, LED's and button handling
|
 |
|
| |
| IS AIN8 |
| Analogue Input Module |
| |
| General information |
- 8 analogue inputs
- Connection via CAN bus
- Precision of inputs is 1%
- Accept 2/3 wire resistive, current,
voltage senders
- UL certified
|
 |
| |
|
|
| |
| IS BIN16/8 |
| Binary Input/Output Module |
| |
| General information |
- 16 inputs and 8 transistor outputs
- Inputs galvanically separated
- 2 pulse inputs (frequency measurement
or pulse counting)
- Connection via CAN bus
- UL certified
|
 |
| |
|
|
| |